John Deere MaxEmerge 5 and ExactEmerge Row Unit Repair Service Manual (TM131219)

Catalog: 
Make: 
Price: US$ 38.00

Complete Repair Service Technical Manual for John Deere MaxEmerge 5 and ExactEmerge Row Unit, with all the workshop information to maintain, repair, and rebuild like professional mechanics.

John Deere MaxEmerge 5 and ExactEmerge Row Unit workshop technical manual (repair) includes:
* Numbered table of contents easy to use so that you can find the information you need fast.
* Detailed sub-steps expand on repair procedure information
* Numbered instructions guide you through every repair procedure step by step.
* Notes, cautions and warnings throughout each chapter pinpoint critical information.
* Bold figure number help you quickly match illustrations with instructions.
* Detailed illustrations, drawings and photos guide you through every procedure.
* Enlarged inset helps you identify and examine parts in detail.

tm131219 - MaxEmerge 5 and ExactEmerge Row Unit Repair Technical Manual Technical Manual.pdf
tm131219 - MaxEmerge 5 and ExactEmerge Row Unit Repair Technical Manual Technical Manual.epub

PRODUCT DETAILS:
Total Pages: 520 pages
File Format: PDF/EPUB/MOBI/AZW (PC/Mac/Android/Kindle/iPhone/iPad; bookmarked, ToC, Searchable, Printable)
Language: English

TABLE OF CONTENTS................1
Section 10: General Information................10
  Group 05: Safety................10
    Recognize Safety Information................13
    Understand Signal Words................14
    Follow Safety Instructions................15
    Handle Fluids Safely—Avoid Fires................16
    Prepare for Emergencies................17
    Avoid Harmful Asbestos Dust................18
    Practice Safe Maintenance................19
    Avoid High-Pressure Fluids................21
    Park Machine Safely................22
    Support Machine Properly................23
    Wear Protective Clothing................24
    Handle Agricultural Chemicals Safely................25
    Work in Clean Area................27
    Service Machines Safely................28
    Work In Ventilated Area................29
    Illuminate Work Area Safely................30
    Replace Safety Signs................31
    Use Proper Lifting Equipment................32
    Remove Paint Before Welding or Heating................33
    Avoid Heating Near Pressurized Fluid Lines................34
    Service Tires Safely................35
    Use Proper Tools................36
    Construct Dealer-Made Tools Safely................37
    Servicing Electronic Control Units................38
    Welding Near Electronic Control Units................39
    Precautions for Welding................40
    Keep Electronic Control Unit Connectors Clean................42
    Decommissioning — Proper Recycling and Disposal of Fluids and Components................43
    Live With Safety................44
  Group 10: Lubricants................10
    Multipurpose Extreme Pressure (EP) Grease................46
    Gear Oil................47
    Alternative and Synthetic Lubricants................48
    Lubricant Storage................49
  Group 15: General Information................11
    Unauthorized Modifications................51
    Machine Photo................52
    Specifications................510
    Sealants and Adhesives Cross-Reference Chart................59
    Metric Bolt and Screw Torque Values................61
    Unified Inch Bolt and Screw Torque Values................63
    Face Seal Fittings Assembly and Installation—All Pressure Applications................65
    Metric Face Seal Fitting Torque Chart—Standard Pressure Applications................66
    SAE Face Seal Fitting Torque Chart—Standard Pressure Applications................68
    External Hexagon Port Plug Torque Chart................70
Section 20: Vacuum System................72
  Group 05: Vacuum System................72
    Adjust Vacuum Gauge................74
    Check Row Vacuum—MaxEmerge 5™ Meters................75
    Check Row Vacuum—ExactEmerge™ Meters................78
    Install Vacuum Sensor Fitting—ExactEmerge™ Meters................79
    Install Vacuum Sensor Fitting—MaxEmerge™ 5 and MaxEmerge™ 5e Meters................81
Section 30: Seed Meters................82
  Group 05: Row Units................82
    Specifications................510
    Remove and Install Row Units—MaxEmerge™ 5 Meters................86
    Remove and Install Row Units—ExactEmerge™ Meters................89
    Remove and Install Rockshaft Mounted Row Units—1795 with MaxEmerge™ 5 Meters................92
    Remove and Install Rockshaft Mounted Row Units—1795 with ExactEmerge™ Meters................95
    Remove and Install Front Center Frame Row Units—1795 with MaxEmerge™ 5 Meters................97
    Check Row Unit Attaching Hardware................100
  Group 10: MaxEmerge™ 5 Seed Meters................82
    Essential or Recommended Tools................384
    Other Material................480
    Specifications................510
    Repair MaxEmerge™ 5 Vacuum Meter................106
    Inspect MaxEmerge™ 5 Vacuum Meter................110
    Remove and Install MaxEmerge™ 5 Vacuum Meter................113
    Remove and Install MaxEmerge™ 5e Vacuum Meter................117
    Remove and Install MaxEmerge™ 5 Vacuum Meter Seal................120
    Remove and Install MaxEmerge™ 5 Seed Disk................121
    Remove and Install MaxEmerge™ 5 Knockout Assembly................122
    Remove and Install MaxEmerge™ 5 Vacuum Meter Brush................123
    Remove and Install MaxEmerge™ 5 Double Eliminator................124
    Calibrate MaxEmerge™ 5 Double Eliminator................128
    Adjust MaxEmerge™ 5 Meter Baffle................131
    Adjust MaxEmerge™ 5 Meter Hub................133
    Install MaxEmerge™ 5 Dust Seal................136
  Group 15: ExactEmerge™ Seed Meters................82
    Essential or Recommended Tools................384
    Other Material................480
    Specifications................510
    Repair ExactEmerge™ Meter................141
    Inspect ExactEmerge™ Meter................144
    Remove and Install ExactEmerge™ Meter with 1.6 bu Hopper................147
    Remove and Install ExactEmerge™ Meter................150
    Remove and Install ExactEmerge™ Meter Seal................152
    Remove and Install ExactEmerge™ Meter Air Duct................153
    Remove and Install ExactEmerge™ Seed Bowl................154
    Remove and Install ExactEmerge™ Knockout Assembly................155
    Remove and Install ExactEmerge™ Baffle Brush................156
    Remove and Install ExactEmerge™ Double Eliminator................158
    Remove and Install ExactEmerge™ Seed Guide................160
    Remove and Install ExactEmerge™ Agitation Strip................163
    Remove and Install ExactEmerge™ Wear Plates................165
    Adjust ExactEmerge™ Meter Hub................166
  Group 20: ExactEmerge™ Seed Placement................83
    Remove and Install BrushBelt™ Cartridge................170
    Disassemble and Assembly BrushBelt™ Cartridge................172
Section 40: Electrical................178
  Group 05: Connector Repair................178
    Essential or Recommended Tools................384
    Other Material................480
    Installation of Repair Wire Assembly (RWA)................189
    Use Electrical Insulating Compound................198
    Using High-Pressure Washers................199
    Connector Information................200
    Repair Procedure R-A................201
    Repair Procedure R-B................206
    Repair Procedure R-C................211
    Repair Procedure R-D................216
    Repair Procedure R-E................219
    Repair Procedure R-F................223
    Repair Procedure R-G................227
    Repair Procedure R-I................230
    Repair Procedure R-J................233
    Repair Procedure R-K................238
    Repair Procedure R-M................241
    Repair Procedure R-N................245
    Repair Procedure R-T................249
    Repair Procedure R-AA................250
    Repair Procedure R-AE................251
    Remove and Install Row Unit Wiring Harness—MaxEmerge™ 5................255
    Remove and Install Row Unit Wiring Harness—MaxEmerge™ 5e................258
    Remove and Install Row Unit Wiring Harness—ExactEmerge™................261
  Group 10: Control Units................178
    Remove and Install Sensor Node Control Unit................265
    Remove and Install ExactEmerge™ Row Unit Control Unit................266
    Remove and Install MaxEmerge™ 5e Row Unit Control Unit................268
    Update Control Units Using Service Advisor™................271
    Programming Control Units................274
  Group 15: Relays, Sensors, and Switches................179
    Specifications................510
    Replace Central Commodity System Push Button Shut-Off Switch................279
    Remove and Install Gauge Wheel Downforce Sensor................280
    Remove and Install Vacuum Sensor—MaxEmerge™ 5 Meters................282
    Remove and Install Vacuum Sensor—MaxEmerge™ 5e Meters................283
    Remove and Install Vacuum Sensor—ExactEmerge™ Meters................285
    Remove and Install Seed Tube Sensor................287
    Remove and Install BrushBelt™ Seed Sensor................288
    Repair BrushBelt™ Seed Sensor................290
    Remove and Install Individual Hydraulic Row Downforce (IRHD) Pressure Sensor................293
  Group 20: Motors................179
    Essential or Recommended Tools................384
    Specifications................510
    Remove and Install MaxEmerge™ 5e Motor................297
    Adjust MaxEmerge™ 5e Motor Alignment................301
    Remove and Install MaxEmerge™ 5e Meter Motor Drive Coupler................303
    Remove and Install ExactEmerge™ Motors................307
    Remove and Install ExactEmerge™ Meter Motor Drive Coupler................312
    Remove and Install BrushBelt™ Motor Drive Coupler................316
Section 50: Drives................319
  Group 05: Chain Drives................319
    Adjust Chain Drive-to-Meter Drive Alignment................322
    Repair Flex Drive................324
  Group 10: Pro-Shaft Drives................319
    Remove and Install Pro-Shaft™ Drive Cable................330
    Remove and Install Front Meter Drive Gear Case................335
    Remove and Install Seed Meter Drive Gear Case................336
    Remove and Install Insecticide Meter Drive Gear Case................339
  Group 15: Electric Drives................319
    Remove and Install Seed Meter Drive Gearbox—MaxEmerge™ 5e................344
    Replace MaxEmerge™ 5e Drive Couplers................347
Section 60: Insecticide and Herbicide Meter................349
  Group 05: Insecticide/Herbicide Meter................349
    Other Material................480
    Specifications................510
    Remove and Install Insecticide/Herbicide Frame................353
    Calibrate Insecticide/Herbicide Meter................356
    Insecticide/Herbicide Meter Drive Alignment................360
Section 70: Row Unit Downforce................363
  Group 05: Mechanical Row Unit Downforce................363
    Specifications................510
    Remove and Install Heavy-Duty Downforce Spring Assembly................366
    Repair Heavy-Duty Downforce Spring Assembly (Regular Parallel Arms)................369
    Repair Heavy-Duty Downforce Spring Assembly (Long Parallel Arms)................371
  Group 10: Pneumatic Row Unit Downforce................363
    Depressurize Pneumatic Downforce System................376
    Inspect Pneumatic Downforce System For Leaks................379
    Inspect and Adjust Air Spring................381
  Group 15: Hydraulic Row Unit Downforce................363
    Essential or Recommended Tools................384
    Specifications................510
    Depressurize Individual Row Hydraulic Downforce (IRHD) System................386
    Prevent Individual Row Hydraulic Downforce (IRHD) System Contamination................387
    Remove and Install Individual Row Hydraulic Downforce (IRHD) Solenoid Valve................389
    Remove and Install Individual Row Hydraulic Downforce (IRHD) Assembly................391
    Disassemble and Assemble Individual Row Hydraulic Downforce (IRHD) Assembly................393
    Individual Row Hydraulic Downforce (IRHD) Flushing Procedure................402
    Individual Row Hydraulic Downforce (IRHD) Air Purge Test................404
    Individual Row Hydraulic Downforce (IRHD) Valve Flush Test................407
    Individual Row Hydraulic Downforce (IRHD) Valve Test................410
Section 80: Ground Tools................413
  Group 05: Seed Openers................413
    Other Material................480
    Specifications................510
    Double Disk Opener Exploded View—MaxEmerge™ 5................418
    Double Disk Opener Exploded View—ExactEmerge™................425
    Remove and Install Double Disk Opener Studs................428
    Remove and Install Double Disk Shield with Insecticide Tube................429
    Remove and Install Seed Tube................430
    Inspect and Adjust Seed Opener Blades................433
    Replace Seed Opener Blades and Seed Tube Guard................437
    Gauge Wheel Bearing Replacement................441
    Remove and Install Gauge Wheel Depth Adjusting Handle................442
    Adjust Gauge Wheels................445
    Remove and Install Gauge Wheel Scrapers................446
    Replace Scrapers................448
    Replace Rigid Scrapers................449
    Replace Rigid Scrapers—ExactEmerge™................453
    Replace One-Piece Scrapers................454
    Replace Heavy-Duty Scrapers................455
  Group 10: Closing Wheels................413
    Other Material................480
    Specifications................510
    Repair Closing Wheels................459
    Repair Closing Wheels—Twin Row................462
    Center Closing Wheels................464
    Adjust Closing Wheel Spacing................465
    Adjust Closing Wheel Assembly—Twin Row................467
    Stagger Closing Wheels................472
    Adjust Closing Wheel Downforce................473
    Disassemble and Assemble Closing Wheel (Rubber)................474
    Disassemble and Assemble Pneumatic Downforce Closing Wheel Assembly................475
    Remove and Install Pneumatic Downforce Closing Wheel Air Spring................477
  Group 15: Row Tillage................414
    Other Material................480
    Specifications................510
    Adjust Coulter Bearing................482
    Disassemble and Assemble Unit Mounted Row Cleaner Unit with Tapered Wheels................484
    Disassemble and Assemble Unit Mounted Screw Adjust Row Cleaner................486
    Remove and Install Floating Row Cleaner for Unit Mounted Coulter................488
    Disassemble and Assemble Pneumatic Row Cleaner with Unit Mounted Coulter................495
    Disassemble and Assemble Pneumatic Row Cleaner without Unit Mounted Coulter................498
    Remove and Install Pneumatic Row Cleaner Air Spring................501
  Group 20: Fertilizer Opener................414
    Specifications................510
    Repair Unit Mounted Single-Disk Fertilizer Opener................511
    Adjust Unit Mounted Single-Disk Fertilizer Opener................513
    Repair Unit Mounted Double-Disk Fertilizer Opener................514
    Replace Double Disk Fertilizer Opener Bearing................516

John Deere MaxEmerge 5 and ExactEmerge Row Unit Repair Service Manual (TM131219)

Logo